drjobs Shift Supv Transmission Control Center 118826

Shift Supv Transmission Control Center 118826

Employer Active

1 Vacancy
drjobs

Job Alert

You will be updated with latest job alerts via email
Valid email field required
Send jobs
Send me jobs like this
drjobs

Job Alert

You will be updated with latest job alerts via email

Valid email field required
Send jobs
Job Location drjobs

Jackson - USA

Monthly Salary drjobs

Not Disclosed

drjobs

Salary Not Disclosed

Vacancy

1 Vacancy

Job Description

Work Place Flexibility: Onsite

Legal Entity:Entergy Services LLC

JOB SUMMARY:
This position is responsible for providing onsite leadership oversight and direction for TCC System Operators responsible for operations activities required to ensure safe reliable and efficient operation of the Entergy Transmission and Distribution (T&D) systems.

JOB DUTIES & RESPONSIBILITIES:

  • Works a rotating 12hour shift schedule providing leadership oversight and direction to the System Operators and Support personnel to ensure the Entergy transmission system is operated in accordance with applicable industry requirements and company guidelines; Liaises with other operational leaders in power delivery power generation nuclear and SPO to ensure the safe reliable and efficient operation of the T&D systems.
  • Ensures that System Operators adhere to applicable procedures and processes to maintain compliance with the realtime operations aspects of the MISO RTO as well as the realtime operations aspects of the NERC Reliability Standards.
  • Provides direct oversight and approval authority over planned transmission equipment outages ensuring Bulk Electric System (BES) reliability is maintained.
  • Provides subject matter expert (SME) guidance to switching operators for planned transmission equipment outages ensuring they are switched and tagged in accordance with Entergys Switching Tagging and Clearance procedure providing safe operations and work zones for field workers.
  • Requests special studies by the RealTime Analysis operator or appropriate support group on an ad hoc basis focused on maintaining system reliability development of operating guides and implementation of local area mitigation plans.
  • Provides guidance and support to the System Operators monitoring transmission lines and substation equipment for thermal overloads voltage support and equipment alarms.
  • Provides oversight and support for the restoration of service following interruptions to the transmission system.
  • Ensures load relief procedures are implemented when necessary to protect BES reliability and regulates transmission voltages within acceptable operating limits.
  • Ensures Operational Leadership team is informed of changes to the BES that may impact reliability.
  • Interfaces with MISO RTO personnel to ensure the safe and reliable operation of the BES.
  • Interfaces with Power Delivery field personnel Industrial & Wholesale Accounts and OpCo Customer Service groups.

MINIMUM REQUIREMENTS:

Minimum Education & Experience Required:

  • 2year Technical Degree or equivalent work experience.
  • 6 years of operations related experience (or 4 years of operations related experience with an engineering degree).
  • Preferred: Previous Engineering Power Delivery Grid Relay or Substation experience.

Minimum Knowledge Skills and Abilities:

  • Solid technical understanding of T&D electrical system operations and specific knowledge of: powerflow analysis techniques; Entergys Switching Tagging & Clearance procedure; applicable NERC standards; and MISO Business Practices that support the reliable operation of the BES.
  • Demonstrated ability to make data driven decisions.
  • Able to build motivate and inspire diverse teams.
  • Proven track record as an Individual Contributor of leading crossfunctional teams managing conflict providing clear direction/role clarity and mentoring employees.
  • Demonstrated ability to lead teams to effectively diagnose problems and implement corrective actions to drive continuous improvement.
  • Preferred: Previous Engineering Power Delivery Grid Relay or Substation experience.

Any Certificates Licenses etc.:

  • NERC System Operator Certification

#LILB1

GB1

#LIONSITE

Primary Location: MississippiJacksonMississippi : Jackson
Job Function: Professional
FLSA Status: Professional

Relocation Option: Level II
Union description/code: NON BARGAINING UNIT

Number of Openings: 1
Req ID: 118826
Travel Percentage:Up to 25

An Equal Opportunity Employer Minority/Female/Disability/Vets. Please click here to view the EEO page or see statements below.

EEO Statement:The Entergy System of Companies provides equal employment opportunities (EEO) to all employees and applicants for employment without regard to race color religion sex gender sexual orientation gender identity or expression national origin age disability genetic information marital status amnesty or status as a protected veteran in accordance with applicable federal state and local laws. The Entergy System of Companies complies with applicable state and local laws governing nondiscrimination in employment in every location in which the company has facilities. This policy applies to all terms and conditions of employment including but not limited to recruiting hiring placement promotion termination layoff recall transfer leaves of absence compensation and training.

The Entergy System of Companies expressly prohibits any form of unlawful employee harassment based on race color religion sex gender sexual orientation gender identity or expression national origin age genetic information disability or veteran status. Improper interference with the ability of the Entergy System of Company employees to perform their expected job duties is absolutely not tolerated.

Accessibility:Entergy provides reasonable accommodations for online applicants. Requests for a reasonable accommodation may be made orally or in writing by an applicant employee or third party on his or her you are an individual with a disability and you are in need of an accommodation for the recruiting process please clickhereand provide your name contact number the accommodation requested and the requisition number that you are requesting the accommodation for. Employee Services will contact you regarding your request.

Additional Responsibilities:As a provider of essential services Entergy expects its employees to be available to work additional hours to work in alternate locations and/or to perform additional duties in connection with storms outages emergencies or other situations as deemed necessary by the company. Exempt employees may not be paid overtime associated with such duties.

Equal Opportunity

The nonconfidential portions of the affirmative action program for individuals with disabilities and protected veterans shall be available for inspection upon request by any employee or applicant for employment. Please to schedule a time to review the affirmative action plan during regular office hours.

WORKING CONDITIONS:
As a provider of essential services Entergy expects its employees to be available to work additional hours to work in alternate locations and/or to perform additional duties in connection with storms outages emergencies or other situations as deemed necessary by the company. Exempt employees may not be paid overtime associated with such duties.

Employment Type

Full-Time

About Company

Report This Job
Disclaimer: Drjobpro.com is only a platform that connects job seekers and employers. Applicants are advised to conduct their own independent research into the credentials of the prospective employer.We always make certain that our clients do not endorse any request for money payments, thus we advise against sharing any personal or bank-related information with any third party. If you suspect fraud or malpractice, please contact us via contact us page.