MISSION:
To produce radiographs to customer and PCC specifications for evaluation of castings.
PRINCIPAL ACCOUNTABILITIES:
- Setup
Objective:to accurately set up castings for radiography.
Essential Job Functions:
- Checks routing to determine x-ray needs on parts.
- Reviews Technique Cards to determine setup requirements including x-ray techniques part positions and film requirements based on Techniques Cards.
- Sets up additional radiographs of defect areas not covered by Technique Cards.
- Prepares daily film requests for darkroom based on production schedules and Technique Cards.
- Sets up castings on tables in x-ray machines including fixturing placement of film cassettes and placement of nameplate identification and penetrameters on film; sets exposures.
- Determines priority of radiographs to be taken.
Other (marginal) Job Functions
- Visually inspects castings for dirt penetrant etc.
X-Ray Operation
Objective:to effectively and accurately operate x-ray machines and produce radiographs within customer specifications.
Essential Job Functions:
- Operates x-ray machine control panels and equipment to take multiple views of castings adjusting radiographic variables such as tube height voltage and exposure times within customer specifications.
- Regularly conducts more than one radiographic examination concurrently and is expected to be able to operate all machines.
- Removes table from machine takes film cassettes to darkroom for processing.
- After darkroom processing checks samples of radiographs on each casting for clarity coverage density and sensitivity; makes changes within customer and PCC specifications; records anychanges made; reshoots films when needed.
- Completes logs and records.
- Meets all production and quality standards.
- Safety
Objective:to take responsibility for and demonstrate safe work practices; to comply with PCC radiation safety practices.
Essential Job Functions:
- Adheres to plant and department safety rules.
- Safely operates all equipment and tools.
- Identifies and reports safety problems.
OTHER (MARGINAL) ACCOUNTABILITIES
- Performs other tasks as directed including darkroom and other x-ray department personnel activities.
ESSENTIAL EQUIPMENT VEHICLES TOOLS AND/OR MACHINERY:
- x-ray machines
- hoists
- pallet jacks
- pentrameters
- styrofoam blocks
- wooden wedges and blocks
- straps and chains
- clamps
- high intensity film viewing light
- lead back-ups
- densitometers
- levels protractors rulers tape measure angle finders
- film processor
- film cassettes
- fixtures
- calculators
- cameras (35 mm box and Polaroid) NDTE departments only
TRAINING
- Training is provided on the job.
- Radiography Level 1 Courses must be completed
- Radiographer Level l Certification must be completed.
- Must re-certify - Level 1 every three years.
QUALIFICATIONS
- Previous radiographic experience and knowledge of basic radiographic techniques is preferred OR An equivalent combination of classroom training and work experience.
- High school graduation of GED. (necessary for NDT certification)
- Ability to perform basic mathematical calculations. (addition subtraction multiplication division)
- Ability to read follow and interpret Technique Cards Quality Control Manuals and other technical specifications.
- Ability to communicate effectively both verbally and in writing.
- Physical ability to perform the essential job functions.
MISSION:To produce radiographs to customer and PCC specifications for evaluation of castings.PRINCIPAL ACCOUNTABILITIES:SetupObjective:to accurately set up castings for radiography.Essential Job Functions:Checks routing to determine x-ray needs on parts.Reviews Technique Cards to determine setup req...
MISSION:
To produce radiographs to customer and PCC specifications for evaluation of castings.
PRINCIPAL ACCOUNTABILITIES:
- Setup
Objective:to accurately set up castings for radiography.
Essential Job Functions:
- Checks routing to determine x-ray needs on parts.
- Reviews Technique Cards to determine setup requirements including x-ray techniques part positions and film requirements based on Techniques Cards.
- Sets up additional radiographs of defect areas not covered by Technique Cards.
- Prepares daily film requests for darkroom based on production schedules and Technique Cards.
- Sets up castings on tables in x-ray machines including fixturing placement of film cassettes and placement of nameplate identification and penetrameters on film; sets exposures.
- Determines priority of radiographs to be taken.
Other (marginal) Job Functions
- Visually inspects castings for dirt penetrant etc.
X-Ray Operation
Objective:to effectively and accurately operate x-ray machines and produce radiographs within customer specifications.
Essential Job Functions:
- Operates x-ray machine control panels and equipment to take multiple views of castings adjusting radiographic variables such as tube height voltage and exposure times within customer specifications.
- Regularly conducts more than one radiographic examination concurrently and is expected to be able to operate all machines.
- Removes table from machine takes film cassettes to darkroom for processing.
- After darkroom processing checks samples of radiographs on each casting for clarity coverage density and sensitivity; makes changes within customer and PCC specifications; records anychanges made; reshoots films when needed.
- Completes logs and records.
- Meets all production and quality standards.
- Safety
Objective:to take responsibility for and demonstrate safe work practices; to comply with PCC radiation safety practices.
Essential Job Functions:
- Adheres to plant and department safety rules.
- Safely operates all equipment and tools.
- Identifies and reports safety problems.
OTHER (MARGINAL) ACCOUNTABILITIES
- Performs other tasks as directed including darkroom and other x-ray department personnel activities.
ESSENTIAL EQUIPMENT VEHICLES TOOLS AND/OR MACHINERY:
- x-ray machines
- hoists
- pallet jacks
- pentrameters
- styrofoam blocks
- wooden wedges and blocks
- straps and chains
- clamps
- high intensity film viewing light
- lead back-ups
- densitometers
- levels protractors rulers tape measure angle finders
- film processor
- film cassettes
- fixtures
- calculators
- cameras (35 mm box and Polaroid) NDTE departments only
TRAINING
- Training is provided on the job.
- Radiography Level 1 Courses must be completed
- Radiographer Level l Certification must be completed.
- Must re-certify - Level 1 every three years.
QUALIFICATIONS
- Previous radiographic experience and knowledge of basic radiographic techniques is preferred OR An equivalent combination of classroom training and work experience.
- High school graduation of GED. (necessary for NDT certification)
- Ability to perform basic mathematical calculations. (addition subtraction multiplication division)
- Ability to read follow and interpret Technique Cards Quality Control Manuals and other technical specifications.
- Ability to communicate effectively both verbally and in writing.
- Physical ability to perform the essential job functions.