drjobs
Requirements of CSSD Technician in one of the best hospital in Mohali Punjab
drjobs
Requirements of CSSD....
drjobs Requirements of CSSD Technician in one of the best hospital in Mohali Punjab العربية

Requirements of CSSD Technician in one of the best hospital in Mohali Punjab

Employer Active

1 Vacancy
The job posting is outdated and position may be filled
drjobs

Job Alert

You will be updated with latest job alerts via email
Valid email field required
Send jobs
drjobs

Job Alert

You will be updated with latest job alerts via email

Valid email field required
Send jobs

Jobs by Experience

drjobs

2-5years

Job Location

drjobs

Mohali - India

Monthly Salary

drjobs

Not Disclosed

drjobs

Salary Not Disclosed

Vacancy

1 Vacancy

Job Description

Req ID : 2464951
o Pack linen instrument trays drums etc received from the wards and OT s. o Check whether the instruments are packed in inner and outer wrapper. o Check that the sharp and micro instruments are packed separately with care. o Check that the proper labeling of the packs are done. o Instruments for E.T.O sterilization received without packing as the packing for E.T.O are done in T.S.S.U. o The register for issuing and receiving the packs are maintained regularly Preparation for Autoclaving o Packing Linen packs used in O.T. Cath Lab & DSA lab are packed in C.S.S.D. o Different types of linen packs are made for e.g. Cardiac packs Neuro packs General packs & gowns etc. o Linen is folded in such a way that while opening and using by the scrub nurse / Surgeons it is not contaminated. o Different methods are used in folding the linen & making the packs. o Signolac Tape (Autoclaving indicator) is applied with each pack. o The thermograph is changed Loading Autoclave Machine & Autoclaving o Set the autoclave for pressure temperature & time according to the kind of load. o Linen & instrument temperature 134 C & pressure 2.25 Kg & time 45 minutes. o Rubber goods temperature 110 C pressure 1.5 Kg & time 15 minutes. o Microbiological indicator is inserted along with each load. o Load the machine by giving space in between the loads. o Close the autoclave properly & recheck the lock.

.

Employment Type

Full Time

About Company

Report This Job
Disclaimer: Drjobpro.com is only a platform that connects job seekers and employers. Applicants are advised to conduct their own independent research into the credentials of the prospective employer.We always make certain that our clients do not endorse any request for money payments, thus we advise against sharing any personal or bank-related information with any third party. If you suspect fraud or malpractice, please contact us via contact us page.